中文版
js_thumb bannerPic
/
/
/
/
Fecal Occult Blood/ Transferrin Combined Detection Kit (Immunochromatography)

Product category

All categories

Contact info

Category:Gastrointestinal diseases

1/1
Number of views:
1000

Fecal Occult Blood/ Transferrin Combined Detection Kit (Immunochromatography)

Retail price
0.0
Market price
0.0
Number of views:
1000
Quantity
-
+
Stock:
0
1
Introduction

[Product Name]

Generic name: Fecal Occult Blood/ Transferrin Combined Detection Kit (Immunochromatography)
[Packaging Size]
1 test/kit, 20 tests/kit

[Intended Use]

This kit is suitable for in vitro qualitative detection of Human hemoglobin (Hb) and Transferrin (Tf) in human stool samples, and used for auxiliary diagnosis of digestive tract bleeding.
The fecal occult blood test is a traditional routine examination item, which has important value for the diagnosis of digestive tract bleeding diseases. The test is often used as a screening index for the diagnosis of digestive tract malignant tumors in the population (especially in the middle-aged and the elderly) [1]. At present, it is considered that the colloidal gold method for fecal occult blood test, that is, determining the Human hemoglobin (Hb) in stools compared with the traditional chemical methods is of high sensitivity and strong specificity, and is not affected by the diet and certain drugs, which has been widely used. Clinical experience shows that the colloidal gold method still has certain false negative results by comparing with the results of digestive tract endoscopy, so the combined detection of transferrin in stools can improve the diagnostic accuracy [2].

[Test Principles]

This kit uses the double antibody sandwich method to detect the Human hemoglobin (Hb) and Transferrin (Tf) in human stool samples. The anti-human hemoglobin detection antibody is coated at the test line Hb on the nitrocellulose membrane, the anti-human transferrin detection antibody is coated at the test line Tf, the goat anti-mouse IgG is coated at the quality control line C, and the marked anti-human hemoglobin and transferrin complexes are coated on the glass cellulose membrane.

During detection, drip the processed sample to the sample well of test cassette. When the sample to be tested contains the target to be tested (hemoglobin or transferrin) and the concentration is higher than the LoD, a reaction complex is formed by the target to be tested and the corresponding target labeled antibody. The reaction complex moves forward along the nitrocellulose membrane under the action of chromatography, and finally agglutinates at the test line to form a red band, indicating that the corresponding test item is positive. On the contrary, if the sample does not contain the target to be tested or the target concentration is lower than the LoD, no red band appears at the test line, indicating that the corresponding test item is negative. Regardless of whether the sample contains the target pathogen to be tested, a red band should appear at the quality control line C of the test strip, as the internal control of whether the chromatography process is normal or whether the reagent is invalid.

[Storage Conditions and Shelf-life]

Storage Conditions: Stored at 4~30°C. Try to use within 1 hour after opening to prevent the opening time too long resulting in the card shell invalid.
Shelf-life: 12 months.
See label for production and expiry dates.

We could not find any corresponding parameters, please add them to the properties table

Relevant attachments

There is currently no content to display
Please add data record on website background.

RELATED PRODUCTS

产品展示
Search
Search

Suzhou Office: Building 1, No. 188, Fuchunjiang Road, High-tech Zone, Suzhou
Beijing Office: Building 2, No. 28, Yuhua Road, Airport Science and Technology Park, Shunyi District, Beijing
Contact number:
+86-10-80497001
Nantong Office: No. 888 Zhujiang Road, Juegang Street, Rudong County, Jiangsu Province
Contact number:
+86-513-80562882(Administration & Human Resources)

                            +86-512-6515-8191(Marketing & Sales)
Company email: sales@hongweitest.com

Macro micro-test

WeChat

Copyright © 2021 Jiangsu Macro & Micro-Test Med-Tech Co.,Ltd.苏ICP备18057655号 苏公网安备 32062302000215号 Power by:300.cn
Suspended
返回顶部